Fastening Patterns
8 Insulation Fasteners & Plates
To achieve FM 1-90 with 8 fasteners and plates utilizing 4’ x 8’ panels the minimum thicknesses on the following product must be met. 2” InsulBase, InsulBase RL, InsulBase NH, SecurShield, SecurShield RL or SecurShield NH. 5/8” SECUROCK or DensDeck Prime. ½” SecurShield HD Plus or SECUROCK with SecurFAST. For more information on fastening patterns, visit section DR-05-23 of the Design References document, linked below.
20 Insulation Fasteners & Plates
To achieve FM 1-150 with 20 fasteners and plates utilizing 4’ x 8’ panels the minimum thicknesses on the following product must be met. 2” InsulBase, InsulBase RL, InsulBase NH, SecurShield, SecurShield RL or SecurShield NH. ½” SECRUOCK or DensDeck Prime. For more information on Insulation Fastening Patterns, visit section DR-05-23 of the Design References document, linked below.
32 Insulation Fasteners & Plates
To achieve FM 1-225 with 32 fasteners and plates utilizing 4’ x 8’ panels the minimum thicknesses on the following product must be met. 2.5” SecurShield HD Composite. 2” InsulBase, InsulBase RL, InsulBase NH, SecurShield, SecurShield RL or SecurShield NH. ½” SECUROCK or DensDeck Prime. For more information on Insulation Fastening Patterns, visit section DR-05-23 of the Design References document, linked below.